CHAPTER 2: Specifications
Power: Local Unit:
5 VDC at up to 120 mA from CPU’s keyboard and
mouse port;
Remote Unit:
From desktop power supply (certified to meet the
relevant international safety standards):
Input: 100 to 240 VAC at 50 to 60 Hz from utility-
power (mains) outlet, through detachable power
cord and IEC 320 male inlet, to external
transformer;
Output (isolated from mains ground): 9 VDC
regulated, at up to 1 amp, from transformer to
Remote Unit
CAUTION!
If you ever need to replace the Remote Unit’s
power supply, the replacement power supply must
have identical output characteristics. Using a
power supply with different output—even if it’s
“almost the same”—could damage your Remote
Unit and the attached equipment.
Size: Each Unit:
Height:
ACU3001A Units, ACU3009A Remote Unit:
1" (2.5 cm);
ACU3022A Units, ACU3009A Local Unit:
1.7" (4.3 cm);
Feet protrude an additional 0.1" (0.2 cm) from
bottom;
Width: 4.3" (11 cm); D-shell connectors protrude an
additional 0.1" (0.2 cm) from left side;
Depth: 3.2" (8.2 cm); additionally, screws protrude less
than 0.1" (0.2 cm) from both the front and the back
Weight: ACU3001A Units, ACU3009A Remote Unit:
8.3 oz. (235 g);
ACU3009A Local Unit: 13.5 oz. (380 g);
ACU3022A Units: 18 oz. (510 g)