Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500
CHAPTER 3: Installation9Switch #4 ON = Self-Diagnostics Mode.OFF = Normal Operation.Switch #5, #6—Block Size Specification.56OFF OFF 80 CharactersOFF
PROTOCOL CONVERTER A/S-2G10NOTESelf-diagnostics will normally display the switches as they are set on the printed circuit board. If the switcheswere
CHAPTER 3: Installation11If SW3, Switch #7 is ON, the A/S-2G will drop DTR when only 32 character spaces remain in the buffer.The A/S-2G will reasser
PROTOCOL CONVERTER A/S-2G123.3.5 CARRIER OPTIONSIf the carrier detect signal is to be driven by the A/S-2G configuration (DCE), the jumper labeled CA
CHAPTER 3: Installation13there is data to be transmitted. Once the A/S-2G receives CTS from the attached device, it will transmitthe data. When the
PROTOCOL CONVERTER A/S-2G143.4.8 COMMAND PASS-THRUTo use the command pass-thru feature, the command must be preceded by &% and terminated by &
CHAPTER 4: Operation4.0 OperationBy its nature, a protocol converter must operate differently in each direction, since it is communicatingwith separ
PROTOCOL CONVERTER A/S-2G16In 3741 protocol, each block contains only one record. If SW3, Switch #5 is OFF, the A/S-2G will fillthe block with spaces
CHAPTER 4: Operation17If SW3, Switch #7 is OFF, the A/S-2G will send an X-OFF (ASCII DC3, 13 Hex) to the asynchronous devicewhen RAM reaches a nearly
PROTOCOL CONVERTER A/S-2G18Data Flow — A/S-2G to Synchronous DeviceBisynchronous Device A/S-2G Converter Asynchronous Device*Assumes block size of 80
FCC STATEMENT1FEDERAL COMMUNICATIONS COMMISSIONANDINDUSTRY CANADARADIO FREQUENCY INTERFERENCE STATEMENTSThis equipment generates, uses, and can radiat
CHAPTER 4: Operation19Data Flow — A/S-2G to Synchronous DeviceBisynchronous Device A/S-2G Converter Asynchronous DeviceACK 1NAKNegative Acknowledgmen
PROTOCOL CONVERTER A/S-2G20Data Flow — A/S-2G to Synchronous DeviceBisynchronous Device A/S-2G Converter Asynchronous DeviceWAKACK 1ACK 0AA 32 32 32 3
CHAPTER 4: Operation21Data Flow — A/S-2G to Synchronous DeviceBisynchronous Device A/S-2G Converter Asynchronous Device*Assumes block size of 80 is s
PROTOCOL CONVERTER A/S-2G224.2 SYNCHRONOUS DEVICE TO ASYNCHRONOUS DEVICE4.2.1 LINE CONTROLWhen the A/S-2G is initially connected to an AC power sour
CHAPTER 4: Operation23Should the A/S-2G receive a DLE EOT (disconnect), the A/S-2G will cycle the synchro-nous DTR leadoff for 2 seconds. This actio
PROTOCOL CONVERTER A/S-2G24Data Flow — A/S-2G to Asynchronous DeviceBisynchronous Device A/S-2G Converter Asynchronous DeviceENQSend data block ASend
CHAPTER 4: Operation25Data Flow — A/S-2G to Asynchronous DeviceBisynchronous Device A/S-2G Converter Asynchronous DeviceSend data block DSend data bl
PROTOCOL CONVERTER A/S-2G26Data Flow — A/S-2G to Asynchronous DeviceBisynchronous Device A/S-2G Converter Asynchronous DeviceSend data block F(last bl
CHAPTER 5: Conversions and Connections275.0 Conversions and Connections5.1 TRANSPARENCY MODE OF OPERATIONWith a special transparency PROM installed
PROTOCOL CONVERTER A/S-2G285.3 RS-232 CABLE CHARTRS-232C pins are defined as follows:1 = Chassis (or Frame or Protective) Ground F-GND, C-GND, or P-G
PROTOCOL CONVERTER A/S-2G2INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement)1. Todas las instrucciones de seguridad y
CHAPTER 5: Conversions and Connections295.4 CODE CONVERSIONSThe conversions used in the standard 2770, 2780, 3741, and 3780 PROMs are shown in the f
PROTOCOL CONVERTER A/S-2G30Characteror ASCII EBCDICGraphic Hex Dir. Hex Comments@40 7CA41 C1B42 C2C43 C3D44 C4E45 C5F46 C6G47 C7H48 C8I49 C9J4A D1K4B
CHAPTER 5: Conversions and ConnectionsUNASSIGNED EBCDIC CODE04 2B 46 58 71 8D AB B7 CE ED08 30 47 59 72 8E AC B8 CF EF09 31 48 62 73 8F AE B9 DA FA17
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746© Copyright 1998. Black Box Corporation
TABLE OF CONTENTS3Table of Contents1.0 Specifications ...
PROTOCOL CONVERTER A/S-2G44.2 Synchronous Device to Asynchronous Device...224.2.1
CHAPTER 1: Specifications51.0 SpecificationsProtocol — Asynchronous: TTY (ASCII)Bisynchronous: 2770, 2780, 3741, and 3780 (EBCDIC)Ports — A: Asyn
PROTOCOL CONVERTER A/S-2G62.0 IntroductionThe Model A/S-2G provides compatibility between an asynchronous, ASCII coded device and asynchronous, EBCDI
CHAPTER 3: Installation73.0 Installation3.1 UNPACKING AND INSPECTIONAfter unpacking the A/S-2G, inspect it for shipping damage. Should there be an
PROTOCOL CONVERTER A/S-2G8Block size for the 2770/2780 is normally limited to 160, but block size is 400 if the 2770/2780 has theMultiple Record Trans