Black Box MT1000A-13-R3 Spezifikationen Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 78
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
MT1000A Installation and Operation Manual Chapter 2 Installation and Setup
Installation and Setup 2-5
LINK A
INTERFACE
BOARD
LINK B
INTERFACE
BOARD
ALARMS MASK
OFF
ON
SW3
ALARMS MASK
OFF ON
CH1
CH2
CH3
CH4
Figure 2-1 MT1000A Main Board, Internal Settings
Table 2-1. MT1000A Switch Settings
Switches Description Values Factory
Setting
SW3
Tributary Alarms
Mask
Along with the software, controls the
operation of the alarms and whether
they are ignored or processed
SW3-1 sets CH 1
SW3-2 sets CH 2
SW3-3 sets CH 3
SW3-4 sets CH 4
OFF—The decision whether the
alarm (of the specific channel) is
masked or not is determined by
the software setting.
ON—Mask the channel. This
channel will not request a relay
activation command. The software
will indicate the stattus of this
channel, but the status cannot be
changed via the software.
OFF
Seitenansicht 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 77 78

Kommentare zu diesen Handbüchern